Publications |
||||||
Noise Property and Experimental Design | ||||||
Pulse Sequences and Technical Issues | ||||||
Selective Applications | ||||||
Reviews | ||||||
Noise Property and Experimental Design | ||||||
Experimental Design and the Relative Sensitivity of BOLD and Perfusion fMRI | ||||||
G. K. Aguirre, J. A. Detre, E. Zarahn and D. C. Alsop NeuroImage 15, 488–500 (2002) |
||||||
Arterial Spin Labeling Perfusion fMRI With Very Low Task Frequency | ||||||
J. Wang, G. K. Aguirre, D. Y. Kimberg, A. C. Roc, L. Li
and J. A. Detre Magnetic Resonance in Medicine 49:796–802 (2003) |
||||||
Empirical Analyses of Null-Hypothesis Perfusion FMRI Data at 1.5 and 4 T | ||||||
J. Wang, G. K. Aguirre, D. Y. Kimberg and J. A. Detre NeuroImage 19: 1449–1462 (2003) |
||||||
To Smooth or Not To Smooth - ROC Analysis of Perfusion FMRI Data | ||||||
J. Wang, Z. Wang, G. K. Aguirre, and J. A. Detre Magnetic Resonance Imaging 23:75-81 (2005)
|
||||||
Pulse Sequences and Technical Issues | ||||||
Reduced Transit-Time Sensitivity in Noninvasive Magnetic Resonance Imaging of Human Cerebral Blood Flow | ||||||
D. C. Alsop and J.A. Detre Journal of Cerebral Blood Flow and Metabolism 16:1236-1249 (1996) |
||||||
Multisection Cerebral Blood Flow MR Imaging with Continuous Arterial Spin Labeling. | ||||||
D. C. Alsop and J.A. Detre Radiology 208:410-416 (1998) |
||||||
Perfusion and Transit Time Changes During Task Activation Determined with Steady-State Arterial Spin Labeling | ||||||
J. B. Gonzalez-At, D. C. Alsop and J. A. Detre Magnetic Resonance in Medicine 43:739-746 (2000) |
||||||
Comparison of Quantitative Perfusion Imaging Using Arterial Spin Labeling at 1.5 and 4.0 Tesla | ||||||
J. Wang, D. C. Alsop, L. Li, J. Listerud, J. B. Gonzalez-At,
M. D. Schnall and J. A. Detre Magnetic Resonance in Medicine 48:242–254 (2002) |
||||||
Arterial Transit Time Imaging With Flow Encoding Arterial Spin Tagging (FEAST) | ||||||
J. Wang, D. C. Alsop, H. K. Song, J. A. Maldjian, K. Tang,
A. E. Salvucci and J. A. Detre Magnetic Resonance in Medicine 50:599–607 (2003) |
||||||
Reduced Susceptibility Effects in Perfusion FMRI with Single-Shot Spin-Echo EPI Acquisitions at 1.5 Tesla | ||||||
J. Wang, L. Li, A. C. Roc, D. C. Alsop, K. Tang, N. S.
Butler, M. D. Schnall and J. A. Detre Magnetic Resonance Imaging 22:1-7 (2003) |
||||||
Amplitude Modulated Continuous Arterial Spin Labeling Perfusion MRI using a Single Coil at 3.0T - Feasibility Study | ||||||
J. Wang, Y. Zhang, R.L. Wolf, A.C. Roc, D. C. Alsop and J. A. Detre Radiology 235:218-228 (2005) |
||||||
Selective Applications | ||||||
Noninvasive MRI Evaluation of Cerebral Blood Flow in Cerebrovascular Disease | ||||||
J. A. Detre, D. C. Alsop, L. R. Vives, L. Maccotta, J.
W. Teener, E. C. Raps Neurology 50:633-641 (1998) |
||||||
Noninvasive Magnetic Resonance Imaging Evaluation of Cerebral Blood Flow With Acetazolamide Challenge in Patients With Cerebrovascular Stenosis | ||||||
J. A. Detre, O. B. Samuels, D. C. Alsop, J. B. Gonzalez-At,
S. E. Kasner, and E. C. Raps Journal of Magnetic Resonance Imaging 10:870-875 (1999) |
||||||
Assessment of Cerebral Blood Flow in Alzheimer's Disease by Spin-Labeled Magnetic Resonance Imaging | ||||||
D. C. Alsop, J.A. Detre and M. Grossman Annual Neurology 47:93-100 (2000) |
||||||
Magnetic Resonance Perfusion Imaging in Acute Ischemic Stroke Using Continuous Arterial Spin Labeling | ||||||
J. A. Chalela, D. C. Alsop, J. B. Gonzalez-At, J. A. Maldjian,
S. E. Kasner and J. A. Detre Stroke 31:680-687 (2000) |
||||||
Pediatric Perfusion Imaging Using Pulsed Arterial Spin Labeling | ||||||
J. Wang, D. J. Licht, G.-H. Jahng, C.-S. Liu, J. T. Rubin,
J. Haselgrove, R. A. Zimmerman and J. A. Detre Journal of Magnetic Resonance Imaging 18:404–413 (2003) |
||||||
Reviews | ||||||
Technical Aspects and Utility of fMRI using BOLD and ASL | ||||||
J.
A. Detre and J. Wang Clinical Neurophysiology 113:621–634 (2002) |
||||||
Perfusion Magnetic Resonance Imaging with Continuous Arterial Spin Labeling: Methods and Clinical Applications in the Central Nervous System | ||||||
J.
A. Detre and D. C. Alsop European Journal of Radiology 30:115–124 (1999) |
||||||